2 Prepare fuel system for extended storage as follows:
A Allow engine to cool down.
B Depress latch and remove (slide down) the lower filter cover.
C Remove the water separating fuel filter.
D Pour out a small amount of fuel into a suitable container, then add
approximately 2 fluid ounces (60 ml) of Quicksilver 2-Cycle Out-
board Oil to fuel in the water separating fuel filter.
E Install water separating fuel filter.
F Start and run engine at idle speed until the water separating fuel
filter and fuel injection system are empty and engine stops.
G Remove and discard water separating fuel filter.
H Install new filter.