SECTION 6
CMD-4081850 / 90-860094030 SEPTEMBER 2003 Page 129
7. Remove the seawater pump outlet hose from top of seawater pump. Drain the hose.
a
75301
D4.2L D-Tronic Engine (All Similar)
a-Seawater pump outlet hose
8. Repeatedly clean out drain holes using a stiff piece of wire. Do this until entire system
is drained.
CAUTION
Avoid water entering boat. Do not unplug seawater inlet hose unless a seacock is
present and it is closed.
9. Remove hose at seawater strainer and drain hose completely. Drain and empty
seawater strainer. Reconnect hose and tighten hose clamps securely. Install washer
and drain plug.
71362
b
a
c
c
a-Seawater strainer
b-Drain plug and washer
c-Hose