200/225 OPTIMAX DTS
90-10234050 Page 21 / 42
Ensure the wiring harness connected to the command module will reach all the
connection points.
3691
a
b
c
c
a - DTS command module
b - Clamp or cable tie
c - CAN link harness
Battery Cable Size For Outboard Models
IMPORTANT: Only use copper battery cables. Do not use aluminum cables for any
outboard marine installations.
If longer battery cables are required, the wire gauge size must increase. See chart
following for correct wire gauge size.
DTS L models are equipped with 3.7 m (12 ft.) cables. DTS XL and XXL models are
not shipped with battery cables.
a
b
or70
a - Wire gauge size b - Battery cable length